My contractor just finished installing my Izzi whirlpool bath, and it is not working. Prior to installing it, we plugged it in and the motor ran fine. What could the problem be?
1. First check the power source in the main panel and under the tub deck. Make sure the plug is plugged in and that there is not a GFCI that is tripped under the deck. If you are unsure, try another appliance on this outlet such as a hair dryer.
2. If you have power and the pump still will not operate, check the air switch by pressing the air button and listening for a click at the motor access. You may need a second person for this. If you don’t hear the switch clicking as the air button is pressed, check to see if the clear ¼ inch clear air tube is connected to the back of the motor. Occasionally, the air tube can be dislodged when sliding the whirlpool bath into the framing. If this is the case, reinsert the hose onto the pump air switch nipple and retest. If this doesn’t solve the problem, please call Izzi service at 800-214-7440
3. It is also possible, that the pump was in the on position when the power to the house was turned on. This will cause the motor to run dry and if not turned off within 15 minute, will over heat and seize the motor. If this is the case, the motor will hum and kick the breaker.
My Izzi whirlpool bathtub pump motor, just hums, and kicks the breaker in my garage. What would cause this?
It is possible that the pump was run dry and is damaged. If the motor is run without water for 15 minute or more, the pump wet end will over heat and seize the motor. If this is the case, the motor will hum and kick the breaker. You may also have a defective motor. Please call Izzi service at: 800-214-7440
I have an Izzi whirlpool bath, and I have a problem with the air volume control. There is air coming out of only four of the five jets. How can I solve this problem?
The problem is caused by one of the jets being clogged by debris from the job site. Quite often this is caused by mud daubers and spiders that build their nest in the whirlpool pipes by entering the jet orifice. These clogs will usually be cleared on their own, but can be manually clear with a small wire inserted into each jet orifice. It‘s not always the problem jets with the air issue where you will find the obstruction. As a precaution during construction, try to keep the trades from dumping garbage in the tub, this makes it easier for insects to drag foreign debris into the jet system